Cellular Imaging Instrumentation Accessories
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (7)
- (2)
- (4)
- (1)
- (1)
- (1)
- (15)
- (1)
- (11)
- (2)
- (16)
- (1)
- (1)
- (15)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (1)
- (1)
- (1)
- (1)
- (45)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (2)
- (4)
- (1)
- (1)
- (2)
- (28)
- (2)
- (1)
- (14)
- (97)
- (1)
- (1)
- (1)
- (12)
- (3)
- (2)
- (1)
Filtered Search Results
Electron Microscopy Sciences Denka Cathode M-3 LaB6, ISI TEM, Standard, 90° cone Angle
Lanthanum Hexaboride is the optimum cathode material for use in SEM, TEM, X-Ray Microanalysis, and Electron Beam Lithography and is a direct replacement for tungsten filaments. It features low potential barrier (work function), high melting point and stability at high temperatures, a low vapor pressure that reduces evaporation lost, and chemical stability. The LaB6 beam is ten times brighter than tungsten, has superior resolution and can be used in a wide range of accelerating voltages. It provides sharp and clear pictures even to the smallest details. Heat and vacuum are the determinants of cathode tip's life, but at 1550 °C and 10-7 Torr, a service life of about 500 hours can be achieved.
Use: ISI TEM
Type: Standard
Angle: 90° cone
Radius: 15 µm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
BIOHIPPO AAV-hSyn-fDIO-TagBFP-WPRE-hGH-polyA
Recombinant adeno associated virus expressing TagBFP under the hSyn promoter with WPRE and hGH polyA elements. The Cre and Flp logic configuration enables expression only after recombination, providing precise targeted control of targeted neurons. Offered under the Biohippo AAVX Series with multiple serotypes available including AAV2/1, AAV2/2, AAV2/5, AAV2/6, AAV2/6m, AAV2/6.2FF, AAV2/7m8, AAV2/8, AAV2/9, AAV2/DJ, AAV2/DJ8, AAV2/Retro, AAV2/PHP.eB, AAV2/PHP.B, AAV2/rh10, AAV2/PHP.S, AAV2/anc80, AAV2/B10, AAV2/olig001, AAV2/BI30, AAV2/BR1, AAV2/MG1.2, AAV1/2, AAV2/MaCPNS1, and AAV2/MaCPNS2. Regular titer is greater than or equal to 2.00E+12 vg per mL, with high titer greater than or equal to 1.00E+13 vg per mL available upon request at no additional cost. Customers may specify preferred serotype and titer when placing orders.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Denka Cathode M-3 LaB6, AMRAY, Standard, 90° cone Angle
Lanthanum Hexaboride is the optimum cathode material for use in SEM, TEM, X-Ray Microanalysis, and Electron Beam Lithography and is a direct replacement for tungsten filaments. It features low potential barrier (work function), high melting point and stability at high temperatures, a low vapor pressure that reduces evaporation lost, and chemical stability. The LaB6 beam is ten times brighter than tungsten, has superior resolution and can be used in a wide range of accelerating voltages. It provides sharp and clear pictures even to the smallest details. Heat and vacuum are the determinants of cathode tip's life, but at 1550 °C and 10-7 Torr, a service life of about 500 hours can be achieved.
Use: AMRAY
Type: Standard
Angle: 90° cone
Radius: 15 µm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Kimball Physics Non-Standard LaB6 Cathode
LaB6 Cathodes are high performance, resistively heated, thermionic electron source for use in SEM, TEM, electronlithography systems, and x-ray sources. They offer an extended life with thousands of hours in clean vacuum, exceptional thermal, chemical, and electrical stability, high brightness/low energy spread with oriented single crystal made from the best quality/high purity material. 90 deg Angle w/non-standard microflat
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Applied Physics LaB6 Cathode for ISI / Topcon
Lanthanum hexaboride (LaB6) and cerium hexaboride (CeB6) cathodes are ideal for many small spot size applications such as SEM, TEM, surface analysis and metrology, and for high current applications such as microwave tubes, lithography, electron-beam welders, X-ray sources and free electron lasers. Greater brightness from low work function yielding higher currents at lower temps than tungsten.
Type: LaB6
Angle: 90°
Tips: 16 mm
Type: non-shunted
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Molecular Devices OPTION ENVIRONMENTAL CONTROL
OPTION ENVIRONMENTAL CONTROL.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Enterprise Technology Solutions 106r01582 Imaging Unit, 145000 Page-Yield
Genuine OEM quality. Accurate image reproduction. Quick and easy installation.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Applied Physics LaB6 Cathode Leica Lithography MVM
Lanthanum hexaboride (LaB6) and cerium hexaboride (CeB6) cathodes are ideal for many small spot size applications such as SEM, TEM, surface analysis and metrology, and for high current applications such as microwave tubes, lithography, electron-beam welders, X-ray sources and free electron lasers. Greater brightness from low work function yielding higher currents at lower temps than tungsten. Cambridge MVM base.
Type: LaB6
Angle: 90°
Tips: 20 mm
Type: non-shunted
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Molecular Devices Automated Cell Imaging System, Brightfield, Fluorescence, Digital Confocal
Compact automated cell imaging and analysis system for fast acquisition and entry-level high-content workflows. Supports brightfield, fluorescence, and Digital Confocal 2D imaging with autofocus and live preview, and uses icon-driven software with preconfigured protocols to simplify common cell-based assays.
- Automated brightfield, fluorescence, and Digital Confocal 2D imaging.
- User-exchangeable objectives with a 6-position automated turret.
- Standard 4x NA 0.13 and 10x NA 0.32 objectives; optional 20x, 40x, and 63x available.
- User-exchangeable filter cubes; standard FITC included; additional DAPI, CFP, TRITC, and Cy5 options.
- Icon-driven acquisition and analysis software with preconfigured protocols for common assays.
- Supports 6- to 384-well microplates, slides, and 35 mm culture dishes.
- Optional environmental control for live-cell, time-lapse experiments.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Applied Physics LaB6 Cathode for Amray
Lanthanum hexaboride (LaB6) and cerium hexaboride (CeB6) cathodes are ideal for many small spot size applications such as SEM, TEM, surface analysis and metrology, and for high current applications such as microwave tubes, lithography, electron-beam welders, X-ray sources and free electron lasers. Greater brightness from low work function yielding higher currents at lower temps than tungsten.
Type: LaB6
Angle: 90°
Tips: 16 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Miltenyi Biotec, Inc. MACSwell One Imaging Frames
MACSwell Imaging Frames for the use of microscope slides for the MACSima™ Imaging System.
This product is subject to the following: Miltenyi Biotec, Inc. Terms and Conditions of Sale For Products and Services
TA Instruments External Filter PCA 320-390 Nm, for Use with Omnicure S2000 Photometer and External Filter Adapter, Provides Controlled Wavelength Range
Waters TA Instruments External Filter PCA (320-390 nm) is designed for use with the Omnicure S2000 photometer when equipped with the external filter adapter (P/N: 935014.901). It allows researchers to conduct photocalorimetry studies using a more controlled and narrow wavelength range, enhancing accuracy in UV curing material analysis. Built with precision optical components, this filter delivers consistent performance and durability. It is ideal for laboratories requiring tailored wavelength studies within the PCA system.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Cayman Chemical PAMAM Dendrimer G6.0 Succinamic Acid (water solution), 100 mg
A succinamic acid-terminated PAMAM dendrimer; ~76 Å in diameter in PBS and has 256 surface groups; does not induce mortality in zebrafish embryos at 100 ppm in the tank water
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Applied Physics LaB6 Cathode for JEOL
Lanthanum hexaboride (LaB6) and cerium hexaboride (CeB6) cathodes are ideal for many small spot size applications such as SEM, TEM, surface analysis and metrology, and for high current applications such as microwave tubes, lithography, electron-beam welders, X-ray sources and free electron lasers. Greater brightness from low work function yielding higher currents at lower temps than tungsten.
Type: LaB6
Angle: 60°
Tips: 5 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Vector Laboratories VectaCell™ Trolox Antifade Reagent for Live Cell Imaging, 2 ml
Specialty Products. VectaCell Trolox Antifade Reagent for Live Cell Imaging is a stock solution of the antioxidant Trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid) in filtered ethanol. Trolox is a water-soluble and cell-permeable analog of vitamin E that efficiently prevents formation of reactive oxygen species such as singlet oxygen (1O2), superoxide anion (O2-) or hydrogen peroxide (H2O2). These can lead to photo-bleaching as well as oxidative damage in cells. While reducing the light intensity usually decreases fading, it also reduces the assay sensitivity. This product contains both Trolox and its oxidized form Trolox-quinone. Trolox has been shown to have a cytoprotective effect and low cytotoxicity for different cell lines and this redox system has been shown to reduce photo-bleaching and blinking during live cell imaging.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More